قد تكون الصورة تمثيلية.
راجع المواصفات للحصول على تفاصيل المنتج.
S-80828CLUA-B6NT2U

S-80828CLUA-B6NT2U

Product Overview

Category

S-80828CLUA-B6NT2U belongs to the category of integrated circuits (ICs).

Use

This product is commonly used as a voltage detector in various electronic devices.

Characteristics

  • Voltage detection range: 0.8V to 10.0V
  • Accuracy: ±1.0%
  • Low current consumption: 1.0μA (typ.)
  • Operating temperature range: -40°C to +85°C
  • Output type: CMOS output
  • Package type: SOT-89-5
  • Lead-free and RoHS compliant

Package and Quantity

The S-80828CLUA-B6NT2U is available in a SOT-89-5 package. Each package contains one unit of the IC.

Specifications

Pin Configuration

The S-80828CLUA-B6NT2U has the following pin configuration:

| Pin Number | Pin Name | Description | |------------|----------|-------------| | 1 | VDD | Power supply input | | 2 | GND | Ground reference | | 3 | RESET | Reset output | | 4 | EN | Enable input | | 5 | VOUT | Output voltage |

Functional Features

  • Voltage detection: The S-80828CLUA-B6NT2U can accurately detect voltages within the range of 0.8V to 10.0V.
  • Reset output: When the detected voltage falls below the specified threshold, the RESET pin goes low, indicating a reset condition.
  • Enable input: The EN pin allows for enabling or disabling the voltage detection function.

Advantages

  • Wide voltage detection range: The S-80828CLUA-B6NT2U can detect a wide range of voltages, making it suitable for various applications.
  • Low current consumption: With a low current consumption of 1.0μA, this IC helps conserve power in battery-operated devices.
  • Compact package: The SOT-89-5 package offers a compact form factor, making it suitable for space-constrained designs.

Disadvantages

  • Limited voltage detection accuracy: While the S-80828CLUA-B6NT2U provides a reasonable accuracy of ±1.0%, it may not be suitable for applications requiring higher precision.

Working Principles

The S-80828CLUA-B6NT2U operates based on a built-in voltage reference and comparator circuit. It continuously monitors the input voltage and compares it with the preset threshold. When the voltage falls below the threshold, the reset output is activated.

Application Field Plans

The S-80828CLUA-B6NT2U finds applications in various electronic devices where voltage monitoring and reset functionality are required. Some potential application fields include: - Battery-powered devices - Microcontrollers and microprocessors - Power management systems - Industrial automation equipment

Alternative Models

For those seeking alternative options, the following models provide similar functionality to the S-80828CLUA-B6NT2U: - S-80828CNMC-B8JT2G - S-80828CNNC-B8JT2G - S-80828CLY-B6NT2U

These alternative models offer comparable voltage detection ranges and package options.

In conclusion, the S-80828CLUA-B6NT2U is an integrated circuit commonly used as a voltage detector. Its wide voltage detection range, low current consumption, and compact package make it suitable for various applications. However, its limited voltage detection accuracy may not be ideal for high-precision applications.

قم بإدراج 10 أسئلة وإجابات شائعة تتعلق بتطبيق S-80828CLUA-B6NT2U في الحلول التقنية

Sure! Here are 10 common questions and answers related to the application of S-80828CLUA-B6NT2U in technical solutions:

1. What is the S-80828CLUA-B6NT2U? - The S-80828CLUA-B6NT2U is a voltage detector IC (integrated circuit) manufactured by a specific company.

2. What is the purpose of the S-80828CLUA-B6NT2U? - The purpose of this IC is to monitor and detect voltage levels in electronic circuits or systems.

3. What is the operating voltage range of the S-80828CLUA-B6NT2U? - The operating voltage range of this IC is typically between 1.6V and 6.0V.

4. How does the S-80828CLUA-B6NT2U work? - This IC works by comparing the input voltage with a reference voltage, and when the input voltage crosses a certain threshold, it triggers an output signal.

5. What is the output type of the S-80828CLUA-B6NT2U? - The output type of this IC is an open-drain output.

6. What is the maximum current that the S-80828CLUA-B6NT2U can sink? - The maximum sinking current of this IC is typically around 100mA.

7. Can the S-80828CLUA-B6NT2U be used for overvoltage protection? - No, this IC is not designed for overvoltage protection. It is primarily used for voltage monitoring and detection.

8. Is the S-80828CLUA-B6NT2U suitable for battery-powered applications? - Yes, this IC is suitable for battery-powered applications as it has a low quiescent current and wide operating voltage range.

9. What is the temperature range for the S-80828CLUA-B6NT2U? - The temperature range for this IC is typically between -40°C and +85°C.

10. Can the S-80828CLUA-B6NT2U be used in automotive applications? - Yes, this IC is suitable for automotive applications as it meets the necessary standards and has a wide operating temperature range.

Please note that the answers provided here are general and may vary depending on the specific datasheet and application requirements of the S-80828CLUA-B6NT2U.