قد تكون الصورة تمثيلية.
راجع المواصفات للحصول على تفاصيل المنتج.
MAX16056ATA17+

MAX16056ATA17+ - English Editing Encyclopedia Entry

Product Overview

Category

MAX16056ATA17+ belongs to the category of integrated circuits (ICs).

Use

This product is commonly used for voltage monitoring and reset functions in various electronic devices.

Characteristics

  • Voltage monitoring and reset functionality
  • Low power consumption
  • Wide operating temperature range
  • Small form factor
  • High accuracy

Package

The MAX16056ATA17+ is available in a small Thin SOT23-6 package.

Essence

The essence of MAX16056ATA17+ lies in its ability to monitor voltage levels and provide reset signals, ensuring proper functioning of electronic devices.

Packaging/Quantity

This product is typically packaged in reels or tubes, with a quantity of 3000 units per reel/tube.

Specifications

  • Supply Voltage Range: 1.6V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Reset Threshold Accuracy: ±1.5%
  • Quiescent Current: 2µA (typical)
  • Reset Timeout Period: 140ms (typical)

Detailed Pin Configuration

The MAX16056ATA17+ has the following pin configuration:

  1. VCC: Power supply input
  2. GND: Ground reference
  3. MR: Manual reset input
  4. RESET#: Active-low reset output
  5. TH: Threshold voltage input
  6. CT: Capacitor connection for reset timeout adjustment

Functional Features

  • Voltage Monitoring: The MAX16056ATA17+ continuously monitors the input voltage and compares it with the threshold voltage.
  • Reset Generation: When the input voltage falls below the threshold voltage, the device generates a reset signal on the RESET# pin.
  • Manual Reset: The MR pin allows for manual reset control, overriding the automatic reset function.
  • Adjustable Reset Timeout: The reset timeout period can be adjusted using an external capacitor connected to the CT pin.

Advantages and Disadvantages

Advantages

  • High accuracy voltage monitoring
  • Low power consumption
  • Small form factor
  • Wide operating temperature range

Disadvantages

  • Limited reset timeout adjustment range
  • Single threshold voltage option

Working Principles

The MAX16056ATA17+ operates by continuously monitoring the input voltage. When the voltage falls below the threshold voltage, it triggers a reset signal. The reset signal remains active until the voltage rises above the threshold or a manual reset is initiated.

Detailed Application Field Plans

The MAX16056ATA17+ finds applications in various electronic devices that require voltage monitoring and reset functionality. Some potential application fields include: - Microcontrollers - Embedded systems - Power management circuits - Battery-powered devices - Industrial automation

Detailed and Complete Alternative Models

  • MAX16055ATA17+: Similar to MAX16056ATA17+, but with a different reset timeout period.
  • MAX16057ATA17+: Similar to MAX16056ATA17+, but with additional features such as adjustable threshold voltage.

In conclusion, the MAX16056ATA17+ is a versatile integrated circuit that provides accurate voltage monitoring and reset functions. Its small form factor, low power consumption, and wide operating temperature range make it suitable for various electronic applications. However, it has limitations in terms of reset timeout adjustment range and single threshold voltage option.

قم بإدراج 10 أسئلة وإجابات شائعة تتعلق بتطبيق MAX16056ATA17+ في الحلول التقنية

Sure! Here are 10 common questions and answers related to the application of MAX16056ATA17+ in technical solutions:

  1. Q: What is the MAX16056ATA17+?
    A: The MAX16056ATA17+ is a low-power, voltage-monitoring circuit designed for use in various technical solutions.

  2. Q: What is the operating voltage range of the MAX16056ATA17+?
    A: The operating voltage range of the MAX16056ATA17+ is from 1.6V to 5.5V.

  3. Q: How does the MAX16056ATA17+ monitor voltage levels?
    A: The MAX16056ATA17+ monitors voltage levels by comparing the input voltage with a preset threshold voltage.

  4. Q: Can the threshold voltage be adjusted in the MAX16056ATA17+?
    A: Yes, the threshold voltage can be adjusted using external resistors.

  5. Q: What is the typical accuracy of the MAX16056ATA17+?
    A: The typical accuracy of the MAX16056ATA17+ is ±1.5%.

  6. Q: Does the MAX16056ATA17+ have any built-in hysteresis?
    A: Yes, the MAX16056ATA17+ has a built-in hysteresis of 50mV.

  7. Q: What is the quiescent current consumption of the MAX16056ATA17+?
    A: The quiescent current consumption of the MAX16056ATA17+ is typically 1.5µA.

  8. Q: Can the MAX16056ATA17+ generate an interrupt signal?
    A: Yes, the MAX16056ATA17+ can generate an active-low interrupt signal when the monitored voltage crosses the threshold.

  9. Q: Is the MAX16056ATA17+ suitable for battery-powered applications?
    A: Yes, the low quiescent current and wide operating voltage range make the MAX16056ATA17+ suitable for battery-powered applications.

  10. Q: What is the package type of the MAX16056ATA17+?
    A: The MAX16056ATA17+ is available in a 6-pin Thin SOT23 package.

Please note that these answers are general and may vary depending on the specific application and requirements.