P51-3000-A-P-I12-4.5OVP-000-000

P51-3000-A-P-I12-4.5OVP-000-000

Product Overview

Category

The P51-3000-A-P-I12-4.5OVP-000-000 belongs to the category of precision pressure transducers.

Use

It is used for accurately measuring and monitoring pressure in various industrial applications.

Characteristics

  • High precision
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-3000-A-P-I12-4.5OVP-000-000 lies in its ability to provide accurate and reliable pressure measurements in demanding environments.

Packaging/Quantity

The product is usually packaged individually and is available in single-unit quantities.

Specifications

  • Model: P51-3000-A-P-I12-4.5OVP-000-000
  • Pressure Range: 0-3000 psi
  • Output: 4-20 mA
  • Overpressure: 4.5 times rated pressure
  • Electrical Connection: Integral cable

Detailed Pin Configuration

The detailed pin configuration of the P51-3000-A-P-I12-4.5OVP-000-000 includes: - Pin 1: Power supply + - Pin 2: Power supply - - Pin 3: Signal output + - Pin 4: Signal output -

Functional Features

  • High accuracy and repeatability
  • Built-in overpressure protection
  • Wide compatibility with various liquids and gases
  • Long-term stability and reliability

Advantages and Disadvantages

Advantages

  • Accurate and reliable pressure measurements
  • Robust construction for durability
  • Suitable for diverse industrial applications

Disadvantages

  • Higher initial cost compared to standard pressure sensors
  • Requires periodic calibration and maintenance

Working Principles

The P51-3000-A-P-I12-4.5OVP-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an electrical signal representing the pressure measurement.

Detailed Application Field Plans

The P51-3000-A-P-I12-4.5OVP-000-000 is widely used in industries such as: - Oil and gas - Aerospace - Automotive - Manufacturing - Process control

Detailed and Complete Alternative Models

Some alternative models to the P51-3000-A-P-I12-4.5OVP-000-000 include: - P51-2000-A-P-I12-4.5OVP-000-000 - P51-4000-A-P-I12-4.5OVP-000-000 - P51-5000-A-P-I12-4.5OVP-000-000

In conclusion, the P51-3000-A-P-I12-4.5OVP-000-000 precision pressure transducer offers high accuracy, reliability, and robustness, making it suitable for a wide range of industrial applications. Its advanced features and precise measurements make it an essential component in various critical systems.

قم بإدراج 10 أسئلة وإجابات شائعة تتعلق بتطبيق P51-3000-A-P-I12-4.5OVP-000-000 في الحلول التقنية

  1. What is the application of P51-3000-A-P-I12-4.5OVP-000-000?

    • P51-3000-A-P-I12-4.5OVP-000-000 is a pressure transducer commonly used in industrial and technical solutions to measure and monitor pressure in various systems.
  2. What are the typical operating conditions for P51-3000-A-P-I12-4.5OVP-000-000?

    • The typical operating conditions for P51-3000-A-P-I12-4.5OVP-000-000 include a temperature range of -40°C to 85°C and a pressure range suitable for the specific application.
  3. How is P51-3000-A-P-I12-4.5OVP-000-000 installed in a system?

    • P51-3000-A-P-I12-4.5OVP-000-000 is typically installed using standard mounting methods such as threaded connections or flanges, following the manufacturer's installation guidelines.
  4. What are the output signals provided by P51-3000-A-P-I12-4.5OVP-000-000?

    • P51-3000-A-P-I12-4.5OVP-000-000 provides analog output signals such as 4-20 mA or 0-10 V, depending on the configuration and requirements of the system.
  5. Can P51-3000-A-P-I12-4.5OVP-000-000 be used in hazardous environments?

    • Yes, P51-3000-A-P-I12-4.5OVP-000-000 is available in intrinsically safe and explosion-proof versions, making it suitable for use in hazardous environments.
  6. What calibration and maintenance procedures are recommended for P51-3000-A-P-I12-4.5OVP-000-000?

    • Regular calibration and maintenance according to the manufacturer's guidelines are recommended to ensure accurate and reliable performance of P51-3000-A-P-I12-4.5OVP-000-000.
  7. Is P51-3000-A-P-I12-4.5OVP-000-000 compatible with different types of fluids and gases?

    • P51-3000-A-P-I12-4.5OVP-000-000 is compatible with a wide range of fluids and gases, but it's important to verify compatibility for specific applications and consult the manufacturer if necessary.
  8. What is the response time of P51-3000-A-P-I12-4.5OVP-000-000?

    • The response time of P51-3000-A-P-I12-4.5OVP-000-000 depends on the specific model and configuration, and it's important to consider this factor when selecting the transducer for a particular application.
  9. Are there any special considerations for integrating P51-3000-A-P-I12-4.5OVP-000-000 into a control system?

    • Integrating P51-3000-A-P-I12-4.5OVP-000-000 into a control system may require attention to electrical connections, signal conditioning, and compatibility with the existing control infrastructure.
  10. What are the key advantages of using P51-3000-A-P-I12-4.5OVP-000-000 in technical solutions?

    • Some key advantages of using P51-3000-A-P-I12-4.5OVP-000-000 include its high accuracy, reliability, robust construction, and suitability for demanding industrial applications.