Introduction

The P51-500-A-N-I36-20MA is a precision pressure transducer designed for use in industrial applications. This entry provides an overview of the product, including its category, use, characteristics, packaging, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Industrial Sensors
  • Use: Measurement and monitoring of pressure in industrial processes
  • Characteristics: High precision, robust construction, compatibility with various media, wide temperature range
  • Package: Sealed stainless steel housing
  • Essence: Accurate pressure measurement for industrial control and automation
  • Packaging/Quantity: Individually packaged

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA current loop
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Supply Voltage: 10-36 VDC
  • Electrical Connection: Integral cable or connector

Detailed Pin Configuration

The P51-500-A-N-I36-20MA features a standard 4-pin electrical connection: 1. Excitation + 2. Signal + 3. Signal - 4. Excitation -

Functional Features

  • Precise and reliable pressure measurement
  • Compatibility with various industrial fluids and gases
  • Robust construction for harsh environments
  • Easy integration into industrial control systems

Advantages and Disadvantages

Advantages: - High accuracy - Wide operating temperature range - Robust construction - Compatibility with various media

Disadvantages: - Relatively high cost compared to some alternatives - Requires external power supply

Working Principles

The transducer utilizes a strain gauge technology to convert pressure into an electrical signal. When pressure is applied, the strain gauge deforms, causing a change in resistance which is then converted into a proportional current output.

Detailed Application Field Plans

The P51-500-A-N-I36-20MA is suitable for a wide range of industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery - Test and measurement equipment

Detailed and Complete Alternative Models

  • Model A: P51-250-B-N-I24-10MA
  • Model B: P51-1000-C-N-I48-4-20MA
  • Model C: P51-750-D-N-I12-0.5-4.5V

This comprehensive entry provides a detailed understanding of the P51-500-A-N-I36-20MA, covering its basic information, specifications, functional features, advantages and disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

قم بإدراج 10 أسئلة وإجابات شائعة تتعلق بتطبيق P51-500-A-N-I36-20MA في الحلول التقنية

  1. What is P51-500-A-N-I36-20MA?

    • P51-500-A-N-I36-20MA is a pressure transducer with a 4-20mA output signal, commonly used in industrial and technical applications to measure and transmit pressure data.
  2. How does P51-500-A-N-I36-20MA work?

    • This pressure transducer works by converting the applied pressure into an electrical signal (4-20mA) that can be easily interpreted by control systems or data acquisition devices.
  3. What are the typical applications of P51-500-A-N-I36-20MA?

    • Common applications include hydraulic systems, pneumatic systems, HVAC systems, process control, and industrial automation where accurate pressure measurement and transmission are required.
  4. What is the pressure range of P51-500-A-N-I36-20MA?

    • The pressure range of this transducer is 0-500 psi, making it suitable for a wide range of industrial and technical pressure measurement needs.
  5. How accurate is P51-500-A-N-I36-20MA?

    • This transducer typically offers high accuracy, often within ±0.25% of full scale, ensuring precise pressure measurements in various technical solutions.
  6. Can P51-500-A-N-I36-20MA be used in hazardous environments?

    • Yes, some models of this transducer are designed to meet hazardous area certifications, making them suitable for use in potentially explosive atmospheres.
  7. What type of output signal does P51-500-A-N-I36-20MA provide?

    • It provides a 4-20mA output signal, which is a common industry standard for transmitting sensor data over long distances without signal degradation.
  8. Is P51-500-A-N-I36-20MA compatible with different types of control systems?

    • Yes, it is compatible with various control systems and PLCs, making it versatile for integration into different technical solutions.
  9. What is the operating temperature range of P51-500-A-N-I36-20MA?

    • The operating temperature range is typically wide, allowing it to function reliably in harsh environmental conditions, often from -40°C to 85°C (-40°F to 185°F).
  10. How do I calibrate P51-500-A-N-I36-20MA?

    • Calibration procedures may vary, but typically involve applying known pressures and adjusting the transducer's output to match the expected values using calibration equipment and software. Always refer to the manufacturer's guidelines for specific calibration instructions.